8024484/2019-06-06 • © SICK AG • Subject to change without notice 67
Operation via Ethernet (Ethernet interface)
“MF1, distance undercut switching
threshold”eld
Requirement for display
• “MF1 activation” parameter: “On” option
• “Function” parameter: “Distance” option
Parameters Description
Distance
switching
threshold
Enter switching threshold for the MF1 multifunctional output.
Read/write access
• Read and write
Input value
• –300,000 ... 300,000
Unit
• mm
Factory setting
• 1990
Distance
hysteresis
Enter hysteresis for the switching threshold for the MF1 multi-
functional output.
Read/write access
• Read and write
Input value
• 1 ... 300,000
Unit
• mm
Factory setting
• 10
Table 42: “Parameter settings” page – “MF1 distance undercut switching
threshold” eld
“MF1, speed undercut switching
threshold”eld
Requirement for display
• “MF1 activation” parameter: “On” option
• “Function” parameter: “Speed” option
Parameters Description
Speed switching
threshold
Enter switching threshold for MF1 multifunctional output.
Read/write access
• Read and write
Input value
• 0 ... 15,000
Unit
• mm/s
Factory setting
• 5,000