8024484/2019-06-06 • © SICK AG • Subject to change without notice 67
Operation via Ethernet (Ethernet interface)
“MF1, distance undercut switching
threshold”eld
Requirement for display
“MF1 activation” parameter: “On” option
“Function” parameter: “Distance” option
Parameters Description
Distance
switching
threshold
Enter switching threshold for the MF1 multifunctional output.
Read/write access
Read and write
Input value
–300,000 ... 300,000
Unit
mm
Factory setting
1990
Distance
hysteresis
Enter hysteresis for the switching threshold for the MF1 multi-
functional output.
Read/write access
Read and write
Input value
1 ... 300,000
Unit
mm
Factory setting
10
Table 42: “Parameter settings” page – “MF1 distance undercut switching
threshold” eld
“MF1, speed undercut switching
threshold”eld
Requirement for display
“MF1 activation” parameter: “On” option
“Function” parameter: “Speed” option
Parameters Description
Speed switching
threshold
Enter switching threshold for MF1 multifunctional output.
Read/write access
Read and write
Input value
0 ... 15,000
Unit
mm/s
Factory setting
5,000