8024484/2019-06-06 • © SICK AG • Subject to change without notice 69
Operation via Ethernet (Ethernet interface)
“SettingMF2function”eld Requirement for display
• “MF2 activation” parameter: “On” option
Parameters Description
Function Select function for MF2 multifunctional output.
Read/write access
• Read and write
Input value
• 0: Distance / 1: Speed / 2: Service
Factory setting
• Servicing
Active state Select level for the active state for MF2 multifunctional output.
Read/write access
• Read and write
Input value
• 0: high / 1: low
Factory setting
• low
Table 45: “Parameter settings” page – “Setting MF2 functions” eld
“MF2, distance undercut switching
threshold”eld
→ See Page 67, Table 42 “MF1, distance undercut switching threshold”.
“MF2, speed undercut switching
threshold”eld
→ See Page 68, Table 43 “MF1, speed undercut switching threshold”
eld.
“MF2,devicemonitoringcongura-
tion”eld
→ See Page 68, Table 44 “MF1, device monitoring”.
“MFactivationnumber”eld
Parameters Description
MF1 Counts the switching events of the MF1 multifunctional input
and output. You can reset the counter using the “Reset MF1”
button.
Read/write access
• Read and write
Input value
• –2147483648 ... 2147483647
M2 Counts the switching events of the MF2 multifunctional out-
put. You can reset the counter using the “Reset MF2” button.
Read/write access
• Read and write
Input value
• –2147483648 ... 2147483647
Table 46: “Parameter settings” page – “MF1 activation number” eld