Operation via Ethernet (Ethernet interface)
70 © SICK AG • Subject to change without notice • 8024484/2019-06-06
Advanceddevicefunction”eld
Parameters Description
Distance
averagelter
Selectlterdepthforthedistancemeasurementvalues.
Read/write access
Read and write
Input value
0: Fast / 1: Medium / 2: Slow
Factory setting
Medium
Speed average
lter
Selectlterdepthforthespeedvalues.
Read/write access
Read and write
Input value
0: Fast / 1: Medium / 2: Slow
Factory setting
Medium
Measurement
direction
Select measuring direction for the distance.
Read/write access
Read and write
Input value
[+]: positive direction / [-] negative direction
Factory setting
Positive direction
Error
suppression
Select time for error suppression. If there is an error, “0” is
speciedasthemeasuredvalue.
Read/write access
Read and write
Input value
0:O/1:50ms/2:200ms
Factory setting
200 ms
Table 47: “Parameter settings” page – “Advanced device function” eld