Operation via Ethernet (Ethernet interface)
70 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“Advanceddevicefunction”eld
Parameters Description
Distance
averagelter
Selectlterdepthforthedistancemeasurementvalues.
Read/write access
• Read and write
Input value
• 0: Fast / 1: Medium / 2: Slow
Factory setting
• Medium
Speed average
lter
Selectlterdepthforthespeedvalues.
Read/write access
• Read and write
Input value
• 0: Fast / 1: Medium / 2: Slow
Factory setting
• Medium
Measurement
direction
Select measuring direction for the distance.
Read/write access
• Read and write
Input value
• [+]: positive direction / [-] negative direction
Factory setting
• Positive direction
Error
suppression
Select time for error suppression. If there is an error, “0” is
speciedasthemeasuredvalue.
Read/write access
• Read and write
Input value
• 0:O/1:50ms/2:200ms
Factory setting
• 200 ms
Table 47: “Parameter settings” page – “Advanced device function” eld