PROFINET IO interface
96 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“MF1” module parameter
(continued)
Name Description
[MF1] Active
State
Select switching level for MF1 input and output.
Value range
• low
• High
Default value
• low
[MF1 Distance]
threshold [mm]
Enter the value of the distance threshold in mm.
Value range
• –300,000 ... 300,000 mm
Default value
• 1,990 mm
[MF1 Distance]
Hysteresis [mm]
Enter the hysteresis of the distance threshold in mm.
Value range
• 1 ... 300,000 mm
Default value
• 10 mm
[MF1 Speed]
Threshold
Enter speed threshold.
Value range
• 0 ... 15,000 mm/s
Default value
• 5,000 mm/s
[MF1 Speed]
Mode
Select direction for detecting the speed overrun.
Value range
• negative direction [–]
• positive direction [+]
• both directions [+/–]
Default value
• both directions [+/–]
[MF1 Service]
Laser Warning
The output switches when the laser module outputs a warning.
Value range
• o
• on
Default value
• on