8024484/2019-06-06 • © SICK AG • Subject to change without notice 97
PROFINET IO interface
“MF1” module parameter
(continued)
Name Description
[MF1 Service]
Level Warning
The output switches when the level is just within the permissi-
ble range.
Value range
• o
• on
Default value
• on
[MF1 Service]
Temp. Warning
The output switches when the device temperature is within the
limit range.
Value range
• o
• on
Default value
• on
[MF1 Service]
Plausib. Warning
The output switches when the probability is high that the mea-
sured value is not plausible.
Value range
• o
• on
Default value
• on
[MF1 Service]
Not Ready
The output switches when the device is not ready.
Value range
• o
• on
Default value
• on
[MF1 Service]
Heating Status
The output switches when the device heating is switched on.
Value range
• o
• on
Default value
• o