162 FLOWSIC100 Flare-XT · Operating Instructions · 8023761/V 1-0/2020-10 · © SICK Engineering GmbH
Technical data
12 .4
Application Evaluation Datasheet (example)
Fig. 100 Application Evaluation Datasheet (example)
10
-2
10
-1
10
0
10
1
10
2
vog in m/s
0
5
10
15
20
25
Uncertainty in %
min
norm
max
Measurement Uncertainty of Flow
EX-S 135 kHz
% up to
Nominal pipe size in "
pressure in bar(a)
Temperature in K
Speed of sound in m/s
1-path
Hot Tapped
12
300
400
min norm max
Zone 2
m/s
20
0.3
5
% above
Testprojekt
FLARE Gas Application Evaluation Datasheet
1
FLOWSIC100 Flare / FLOWSIC100 Flare-XT
General Information
Project Name
Reference (CRM/ZTA)
TAG No.
Device Type
Path Configuration
Type of installation
12345
654
Process data
Specified uncertainty
by customer
Results
0.03
0.10
0.30
1.00
3.00
10.00
18.72
6.94
4.65
4.31
4.28
4.28
v_max 4.26
in %
Ex-zone
1)
2), 3)
1)
2)
3)
for fully developed flow profiles; based on
extended measurement range based on Active Sound Correlation technology
in the range of 100-130% of last ultrasonic
21.82
100.96
131.25
Molecular weigth in g/mol
Max. velocity in m/s
Max. velocity ASC in m/s
5.49
v_max,AS 9.14
2), 3)
2), 3)
26520Max. flow rate in m³/h
34476Max. flow rate ASC in m³/h
7.9
26.3
78.8
262.7
788.0
2626.8
Q_max
Q_max,AS
in m/s in m³/h
vog Flow rate

Table of Contents