EasyManuals Logo

SICK FLOWSIC100 Flare-XT User Manual

SICK FLOWSIC100 Flare-XT
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
Technical data
FLOWSIC100 Flare-XT · Operating Instructions · 8023761/V 1-0/2020-10 · © SICK Engineering GmbH 163
12 .5
Applications of FLOWSIC100 Flare-XT in a regulated environment
The gas flow meter can be used for emission measurements, which may be subject to one
or more regulations in some jurisdictions. Compliance with all emission regulations
applicable at the site of the installation remains the responsibility of the owner / operator.
When correctly designed and applied, SICK's ultrasonic flow technology meets or exceeds
most regulatory performance requirements. Please contact your SICK representative to
find out about the right flare measurement solution that meets the currently applicable
regulatory requirements.
12 .6 Application ranges
Fig. 101 Exemplary V
max
of 1-path and 2-path solutions dependent on the sound velocity (SOS)
Fig. 102 V
min
with 20% uncertainty of 1-path and 2-path solutions depending on the speed of sound (SOS)
50
60
70
80
90
100
110
0 1020304050607080
130
40
v
max
in ft/s
Nominal pipe size in ″
120
1-path sos = 340 m/s 1-path sos = 430 m/s 1-path sos = 650 m/s
2-path sos = 340 m/s 2-path sos = 430 m/s 2-path sos = 650 m/s
V
max
[m/s]
1-path SOS = 340 m/s
2-path SOS = 340 m/s
1-path SOS = 450 m/s
2-path SOS = 450 m/s
1-path SOS = 650 m/s
2-path SOS = 650 m/s
Nominal size ["]
0.04
0.05
0.06
0.07
0 1020304050607080
0.08
0.03
v
min
in m/s
Nominal pipe size in ″
0.09
0.10
0.11
0.12
0.13
0.14
0.15
0.16
0.17
0.18
0.19
1-path sos = 340 m/s 1-path sos = 450 m/s 1-path sos = 650 m/s
2-path sos = 340 m/s 2-path sos = 450 m/s 2-path sos = 650 m/s
1-path SOS = 340 m/s
2-path SOS = 340 m/s
1-path SOS = 450 m/s
2-path SOS = 450 m/s
1-path SOS = 650 m/s
2-path SOS = 650 m/s
V
min
[m/s]
Welded / dry calibrated / flow calibrated
Nominal size ["]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK FLOWSIC100 Flare-XT and is the answer not in the manual?

SICK FLOWSIC100 Flare-XT Specifications

General IconGeneral
BrandSICK
ModelFLOWSIC100 Flare-XT
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals