7SR11 & 7SR12 Settings & Instruments Guide
©2017 Siemens Protection Devices Limited Chapter 2 Page 7 of 20
SETTINGS MODE
INSTRUMENTS MODE
FAULT DATA MODE
SYSTEM CONFIG
FUNCTION CONFIG
CT
/
VT CONFIG
PHASE U
/O
VOLTAGE
NPS OVERCURRENT
VOLTAGE PROTECTION
SUPERVISION
27
/59
-1
27
/59
-
2
27
/
59-3
27/
59-
4
47-
1
47-2
59NIT
59NDT
CB FAIL
VT SUPERVISION
CT SUPERVISION
BROKEN CONDUCTOR
TRIP CCT SUPERVISION
AUTORECLOSE PROTN
AUTORECLOSE CONFIG
CURRENT PROT
’N
PHASE OVERCURRENT
51-
1
51
-
2
51
-3
51
-
4
50
-1
50
-2
50
-3
50-
4
51N
-
1
51
N
-2
51
N-
3
51N
-
4
50
N-
1
50
N-
2
50
N
-3
50N
-4
VOLTAGE CONT O
/
C
DERIVED E
/F
MEASURED E
/
F
51
G
-1
51G
-
2
51
G-
3
51
G-
4
50
G
-1
50
G-
2
50
G-
3
50
G
-4
51SEF
-
1
51
SEF-
2
51
SEF-
3
51
SEF
-4
50SEF
-
1
50SEF
-2
50
SEF
-3
50SEF
-
4
46IT
46DT
37
-
1
37
-2
SENSITIVE E
/
F
RESTRICTED E/
F
COLD LOAD
NPS OVERCURRENT
UNDER CURRENT
THERMAL
CONTROL
& LOGIC
CIRCUIT BREAKER
QUICK LOGIC
INPUT CONFIG
OUTPUT CONFIG
MAINTENANCE
DATA STORAGE
INPUT MATRIX
BINARY INPUT CONFIG
GENERAL ALARMS
OUTPUT MATRIX
BINARY OUTPUT CONFIG
LED CONFIG
PICK UP CONFIG
CB COUNTERS
I 2T CB WEAR
CONTROL MODE
CB TRAVELLING CLOSE I OPEN
AR
: OUT OF SERVICE
AR
: TRIP
& RECLOSE
AR
: TRIP
&
LOCKOUT
SEF IN
HOTLINE WORKING :
OUT
INST PROT'
N
: IN
IN I OUT
CONFIRM ACTION
CONFIRM ACTION
IN I OUT
IN I OUT
IN I OUT
FAVOURITE METERS
CURRENT METERS
VOLTAGE METERS
DIRECTIONAL
METERS
POWER METERS
ENERGY METERS
THERMAL METERS
AUTORECLOSE METERS
MAINTENANCE METERS
GENERAL ALARM
METERS
BINARY INPUT METERS
BINARY OUTPUT METERS
VIRTUAL METERS
QUICKLOGIC METERS
7
SR
12
____________________________
ENTER to CONTROL
NUMBER OF FAULTS
NEUTRAL OVERVOLTAGE
INRUSH DETECTOR
P/F SHOTS
E
/F SHOTS
SEF SHOTS
EXT SHOTS
MANUAL CB CONTROL
COMMUNICATIONS METERS
DEMAND METERS
COMMUNICATIONS
CLOSE CCT SUPERVISION
DEMAND
TRIP
CONFIG
OUTPUT MATRIX TEST
Set L or R
:
L or R
Set Remote:
L or R
Set Local:
L or R
IN I OUT
IN I OUT
IN I OUT
Set Service:
L or R
IN I OUT
WAVEFORM STORAGE
FAULT STORAGE
FREQUENCY METERS
ENERGY STORAGE
MISCELLANEOUS METERS
WATTMETRIC
METERS
START COUNT
U
/O FREQUENCY
81
-1
81
-2
81
-
3
81
-4
Control Mode is not supported by
7
SR
1102
-
1
*
A
12
-
*
AA
0
models
POWER
SENSITIVE POWER
POWER
PROTECTION
32-
1
32
-2
32S
-1
32S
-2
55
=
1
55
-2
POWER FACTOR
Figure 1.2-2 Menu Structure