9.11 Project overview
In Utilities&Applications, select Scripts > Report scripts to access scripts for generating reports
on all
TOs
Programs, function blocks, functions
Units
Tasks and assigned programs
in the current SIMOTION project.
A script lists the relevant specific objects of the SIMOTION project in an HTML document,
arranged in a tabular format. Once generated, the HTML document opens and is displayed
automatically in the Internet Explorer. The information involved can also be saved from there
in HTML or CSV format or as an Excel file.
9.12 Services and diagnostics without an Engineering System
SIMOTION devices have an integrated web server. The web server supports the display of
diagnostic and system data in standard Internet browsers, even in the absence of an
Engineering System, and the carrying out of project/firmware updates.
For more detailed information, see the
SIMOTION IT Ethernet-based
HMI and Diagnostic Function Diagnostics Manual
.
Diagnostics
9.12 Services and diagnostics without an Engineering System
SIMOTION SCOUT
196 Configuration Manual, 11/2016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION SCOUT and is the answer not in the manual?

Siemens SIMOTION SCOUT Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION SCOUT
CategoryControl Unit
LanguageEnglish

Related product manuals