SIMOTION device Interface As supplied
SIMOTION P320-4 X1 Onboard Ethernet 1 Access to/from Windows:
IP address: 169.254.11.21
Subnet: 255.255.0.0
Access to/from SIMOTION P Runtime:
IP address: 169.254.11.22
Subnet: 255.255.0.0
X3 PROFINET onboard interface
with 3 ports
Supplied without IP address and subnet
SIMOTION D4x5 X126 DP1
X136 DP2 / MPI
PROFIBUS address 2, baud rate 1.5 Mbit/s
PROFIBUS address 2, baud rate 1.5 Mbit/s
X120 IE1/ OP
(Ethernet)
X130 IE2/ NET
(Ethernet)
IP address: 192.168.214.1
Subnet: 255.255.255.0
IP address: 169.254.11.22
Subnet: 255.255.0.0
With optionally inserted CBE30:
X1400 (one PROFINET interface
with 4 ports)
Supplied without IP address and subnet
SIMOTION D4x5-2 DP X126 DP
X136 DP/MPI
PROFIBUS address 2, baud rate 1.5 Mbit/s
PROFIBUS address 2, baud rate 1.5 Mbit/s
X120 P1 PN/IE-OP
(Ethernet)
X127 P1 PN/IE
(Ethernet)
X130 P1 PN/IE-NET
(Ethernet)
Supplied without IP address
and subnet
IP address: 169.254.11.22
Subnet mask: 255.255.0.0
Supplied without IP address and subnet
SIMOTION D4x5-2 DP/PN X126 DP
X136 DP/MPI
PROFIBUS address 2, baud rate 1.5 Mbit/s
PROFIBUS address 2, baud rate 1.5 Mbit/s
X127 P1 PN/IE
(Ethernet)
X130 P1 PN/IE-NET
(Ethernet)
IP address: 169.254.11.22
Subnet mask: 255.255.0.0
Supplied without IP address and subnet
X150 P1-P3 PN
(1 PROFINET interface with
3 ports)
Supplied without IP address and subnet
With the optional inserted
CBE30-2:
X1400 (1 PROFINET interface
with 4 ports)
Supplied without IP address and subnet
SIMOTION D410 DP X21 DP PROFIBUS address 2, baud rate 1.5 Mbit/s
SIMOTlON D410 PN X200 and X201
(1 PROFINET interface with
2 ports)
Supplied without IP address and subnet
SIMOTION D410‑2 DP X21 DP/MPI
X24 DP
PROFIBUS address 2, baud rate 1.5 Mbit/s
PROFIBUS address 2, baud rate 1.5 Mbit/s
X127 P1 PN/IE
(Ethernet)
IP address: 169.254.11.22
Subnet mask: 255.255.0.0