1.4
Protection levels
Overview
The SINUMERIK 808D ADVANCED provides a concept of protection levels for enabling data areas. Different protection
levels control different access rights.
The control system delivered by SIEMENS is set by default to the lowest protection level 7 (without password). If the
password is no longer known, the control system must be reinitialized with the default machine/drive data. All passwords are
then reset to default passwords for this software release.
data; otherwise, all data are lost after rebooting with default machine/drive data.
Protection level
Locked by
Area
0
Siemens password Siemens, reserved
1
Manufacturer password Machine manufacturers
2
Reserved
3-6
End user password
(Default password: "CUSTOMER")
End users
7
No password End users
Protection level 1
Protection level 1 requires a manufacturer password. With this password entry, you can perform the following operations:
Entering or changing part of the machine data and drive data
Conducting NC and drive commissioning
Protection level 3-6
Protection level 3-6 requires an end user password. With this password entry, you can perform the following operations:
Entering or changing part of the machine data and drive data
Editing programs
Setting offset values
Measuring tools
Protection level 7
Protection level 7 is set automatically if no password is set and no protection level interface signal is set. The protection level
7 can be set from the PLC user program by setting the bits in the user interface.
In the menus listed below the input and modification of data depends on the set protection level:
Tool offsets
Work offsets
Setting data
RS232 settings
Program creation/program correction
The number of machine data and drive data which can be read or modified depends on the protection level. You can set the
protection level for these function areas with the display machine data (
USER_CLASS
...).
Setting password
You can set the desired password through the following operating area:
+

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals