Programming and Operating Manual (Milling) 
222  6FC5398-4DP10-0BA1, 01/2014 
 
Entering/modifying work offsets 
Operating sequence 
In case of any problems found when testing the tool offset result, you can proceed through the following steps to make tiny 
adjustment of values: 
 
1.  Select the desired operating area. 
 
2.  Open the list of work offsets. The list contains the values of the basic offset of the programmed 
work offset and the active scaling factors, the mirror status display and the total of all active work 
offsets. 
 
3.  Use the cursor keys to position the cursor bar in the input fiel
ds to be modified and enter the values. 
 
 
 
4.  Confirm your entries. The changes to the work offsets are activated immediately. 
 
Entering/modifying the setting data 
Entering/modifying the setting data 
Operating sequence 
 
1.  Select the desired operating area. 
 
 
2.  Open the setting data window.  
 
 
 
3.  Position the cursor bar in the input fields to be modified and enter the values (see table below for 
the parameter descriptions). 
 
4.  Use this key or move the cursor to confirm your entries.