Indications for IEC 60 870-5-103 are always reported ON / OFF if they are subject to general interrogation for
IEC 60 870-5-103. If not, they are reported only as ON.
New user-defined indications or such newly allocated to IEC 60 870-5-103 are set to ON / OFF and subjected
to general interrogation if the information type is not a spontaneous event (“.._Ev”“). Further information on
indications can be found in detail in the SIPROTEC 4 System Description, Order No. E50417-H1176-C151.
In columns “Event Log”, “Trip Log” and “Ground Fault Log” the following applies:
UPPER CASE NOTATION “ON/OFF”: definitely set, not allocatable
lower case notation “on/off”: preset, allocatable
*: not preset, allocatable
<blank>: neither preset nor allocatable
In the column “Marked in Oscill. Record” the following applies:
UPPER CASE NOTATION “M”: definitely set, not allocatable
lower case notation “m”: preset, allocatable
*: not preset, allocatable
<blank>: neither preset nor allocatable
No. Description Function Typ
e of
Info
rma
tion
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
information number
Data Unit
General Interrogation
- >Back Light on (>Light
on)
Device,
General
SP On
Of
f
* * LED BI BO
- Reset LED (Reset LED) Device,
General
IntS
P
On * * LED BO 16
0
19 1 No
- Stop data transmission
(DataStop)
Device,
General
IntS
P
On
Of
f
* * LED BO 16
0
20 1 Yes
- Test mode (Test mode) Device,
General
IntS
P
On
Of
f
* * LED BO 16
0
21 1 Yes
- Feeder GROUNDED
(Feeder gnd)
Device,
General
IntS
P
* * * LED BO
- Breaker OPENED (Brk
OPENED)
Device,
General
IntS
P
* * * LED BO
- Hardware Test Mode
(HWTestMod)
Device,
General
IntS
P
On
Of
f
* * LED BO
- Clock Synchronization
(SynchClock)
Device,
General
IntS
P_E
v
* * *
- Disturbance CFC
(Distur.CFC)
Device,
General
OUT On
Of
f
* LED BO
F.3
Functions, Settings, Information
F.3 Information List
SIPROTEC 4, 7SJ80, Manual 501
E50417-G1140-C343-A8, Edition 12.2017

Table of Contents

Other manuals for Siemens SIPROTEC 7SJ80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SJ80 and is the answer not in the manual?

Siemens SIPROTEC 7SJ80 Specifications

General IconGeneral
Rated Frequency50/60 Hz
Rated Current1 A / 5 A
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
Current Transformer Inputs4
ApplicationProtection of feeders, motors, transformers, and generators
Rated Voltage100-240 V AC/DC
Communication ProtocolsIEC 61850, Modbus, DNP3, IEC 60870-5-103
DisplayGraphical LCD
MountingFlush mounting
Protection FunctionsOvercurrent, Earth fault
Communication InterfacesEthernet, RS485
HousingPlastic
WeightApprox. 1.5 kg