DP_I
→ Double point indication, intermediate position 00
Drag and drop
Copying, moving and linking function, used at graphics user interfaces. Objects are selected with the mouse,
held and moved from one data area to another.
Earth
The conductive earth whose electric potential can be set equal to zero at every point. In the area of earth elec-
trodes the earth can have a potential deviating from zero. The term "Earth reference plane" is often used for
this state.
Earth (verb)
This term means that a conductive part is connected via an earthing system to the → earth.
Earthing
Earthing is the total of all means and measures used for earthing.
Electromagnetic compatibility
Electromagnetic compatibility (EMC) is the ability of an electrical apparatus to function fault-free in a specified
environment without influencing the environment unduly.
EMC
→ Electromagnetic compatibility
ESD protection
ESD protection is the total of all the means and measures used to protect electrostatic sensitive devices.
EVA
Limiting value, user-defined
ExBPxx
External bit pattern indication via an ETHERNET connection, device-specific → Bit pattern indication
ExC
External command without feedback via an ETHERNET connection, device-specific
ExCF
Command with feedback via an ETHERNET connection, device-specific
ExDP
External double point indication via an ETHERNET connection, device-specific → Double point indication
ExDP_I
External double point indication via an ETHERNET connection, intermediate position 00, device-specific →
Double point indication
ExMV
External metered value via an ETHERNET connection, device-specific
Glossary
SIPROTEC 4, 7SJ80, Manual 551
E50417-G1140-C343-A8, Edition 12.2017

Table of Contents

Other manuals for Siemens SIPROTEC 7SJ80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SJ80 and is the answer not in the manual?

Siemens SIPROTEC 7SJ80 Specifications

General IconGeneral
Rated Frequency50/60 Hz
Rated Current1 A / 5 A
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
Current Transformer Inputs4
ApplicationProtection of feeders, motors, transformers, and generators
Rated Voltage100-240 V AC/DC
Communication ProtocolsIEC 61850, Modbus, DNP3, IEC 60870-5-103
DisplayGraphical LCD
MountingFlush mounting
Protection FunctionsOvercurrent, Earth fault
Communication InterfacesEthernet, RS485
HousingPlastic
WeightApprox. 1.5 kg