106
457420/A
Conguringtheenvironmentalparameters
Environmentalparameterssuchassalinity,andsoundspeedplayanimportantparttopresent
accurateechodata.UsetheEnvironmentparameterstodenethesevalues.Dependingon
thecurrentseaandweatherconditions,youmayneedtochangethesevaluesfrequently.
Context
Inordertoobtainaccurateechoes,itisveryimportantthatthesoundspeedthroughthe
waterissetcorrectly.Severalparametersarerequiredtocalculatethecorrectsoundspeed
value.Iftheseparametersarenotknowntoyou,usethedefaultvalue1494m/s.Thisisa
typicalmeanvalueforsoundspeed.
Procedure
1OpentheSetupmenu.
2SelectEnvironment.
ObservethattheEnvironmentdialogboxopens.
3Specifyifyouworkinfreshorsaltwater.
4Specifythesoundspeed.
5SelectOKtosavetheselectedsettingsandclosethedialogbox.
Relatedtopics
Deningsettingsrelatedtouserpreferencesandindividualcustomizing,page97
Settingupthealarmlimitsforsystemprotection
SafeoperationoftheST90ismadepossibleusingmultiplesensorsthatmonitorthe
operationandtheperformance.Wheneverasuspiciouseventtakesplace,arelevant
message,warningoralarmisprovided.Selectedalarmlimitsmaybeadjustedtotyour
operationalrequirements.
Procedure
1OpentheSetupmenu.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.
Thisdialogboxcontainsanumberofpages
selectedfromthemenuontheleftside.
3OntheleftsideoftheInstallationdialogbox,selectSystemProtectiontoopenthepage.