Transmittingwithxed-timeintervals
YoucansetuptheST90totransmitpingswithaxedtimeinterval.
Context
UseTransmissionModetocontrolhowoftentheST90
shalltransmititsenergyintothewater.Fornormaluse,
chooseMaximum.IfyouchooseMaximum,theST90will
transmit(ping)continuouslyandasoftenaspossible.
IfyouchooseInterval,youmustdenethetimebetween
eachpingwiththePingIntervalfunction.PingInterval
permitsyoutochoosethetime(inmilliseconds)between
eachtransmission(ping).
Procedure
1OpentheOperationmenu.
2SetOperationtoNormal.
3SetTransmissionModetoInterval.
4Specifytheintervalbetweeneachping.
aSelecteithersideofthebuttontochooseavalue.
bSelectthemiddleofthebuttontoopenit.
IfyouhaveakeyboardconnectedtotheST90,youcantypetherequestedvalue.
Youcanalsochangethevaluebyselecting-andholding-themiddleofthe
button,andmovethecursorsideways.Dragthecursorsidewaystoincreaseor
decreasethevalue.Releasethemousebuttonwhenrequestedvalueisshown.
Relatedtopics
Choosingoperatingmodeandkeytransmitparameters,page52
SettinguptheST90formaximumechorefreshrate,page55
Transmittingsinglepings,page56
Operatingprocedures

Table of Contents

Other manuals for Simrad ST90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad ST90 and is the answer not in the manual?

Simrad ST90 Specifications

General IconGeneral
BrandSimrad
ModelST90
CategorySonar
LanguageEnglish

Related product manuals