1
097-55501-01 Issue 6 – June 2003 117
2
5
3
Operational Verification & Configuration
"S0-OUT5C:,090-55581-01-
A,,R4209A,00J21559,D0TPJN0AAA,267799,DS1,"
"S0-OUT6C:,090-55581-01-
A,,R4209A,00J43212,DOTPJN0AAA,267799,DS1,"
>
SYMMBITS 99-10-03 20:55:19
M sc1 COMPLD
"S2-CLK1:,090-55545-01-B,,4209A,,D0C1ZZ0AAA,299465"
"S2-CLK2:,090-55545-01-B,,4209A,,D0C1ZZ0AAA,299465"
"S2-OUT12F:,090-55581-01-
A,,R4209A,00000000,D0TPJN0AAA,267799,,"
"S2-OUT14G:,090-55581-01-
A,,R4209A,00J21577,D0TPJN0AAA,267799,DS1,DS1"
The first set of responses (those that begin with "S0-") identify
hardware in the master shelf. The second set of responses
(those that begin with "S2-") identify hardware in the expansion
shelf. For this example:
• S2- occurs because the rotary switch position was set to 2.
If the switch had been set to 1, these responses would be
S1-. If there were several shelves, the specific shelf is
identified in this response by Sx, where x is the rotary
switch value. Valid choices are 1, 2, 3, and 4.
• S2-CLK1 line identifies that there is an expansion controller
card in the EC1 slot.
• S2-CLK2 line identifies that there is an expansion controller
card in the EC2 slot.
• S2-OUT12F and S2-OUT14G identify that there are output
driver cards in slots 12F and 14G. Note also that the card in
14G has 2 DS1 output connector modules (090-55591-02)
attached in the G group on the back of the shelf.
To actually configure expansion shelf output settings, go to the
Configuration->Output form. On this form you can (see online
help for additional info):
• Select the shelf and output slot that you want to view or
configure. Controls for this are in the upper left. Once
selected, the software queries the TimeHub to determine if
there are actually output driver cards and connector
modules in the selected slot. If so, they will be identified on
the form.
• For DS1 and CC ports you can individually enable/disable
the selected port