097-55501-01 Issue 6 – June 2003 199
2
5
3
Specifications
6.1.14 Power
Connector Type: Terminal block
Connector Labels: Return/–48V (A)
Return/–48V (B)
Connector Location: Rear panel
Voltage: –42 V dc to –60 V dc (each connector)
Current: Master/Remote Shelf: 180 W
Expansion Shelf: 100 W
Recommended Battery
Feed Fuse: 10 A
6.1.15 Shelf Mechanical
Mounting: NEBS 19 in. rack
NEBS 23 in. rack
Rack Mounting Position: Flush
2 in. offset
5 in. offset
Width: 16.6 in.
Height: 10.5 in.
Depth: 11.6 in.
Weight: 14 lb empty
40 lb fully loaded