RUN MED: Service & Maintenance Manual - rev. 1.0
Page 9.6
9.1.15. FORMAT P&P
This function formats a TGS key for Plug&Play mode operation. To select the function, when the
LED matrix shows:
FORMAT P&P
press ENTER to confirm. At the end of the format procedure, hold down the CLEAR key for a few
seconds to exit. The CLEAR key can be pressed at any time to interrupt the procedure and revert to
standby mode.
9.1.16. USER DETECT
This function is able to detect the presence of a user running on the tread belt during an exercise
session. It is possible to configure a minimum speed at which the machine will determine that the
user has stopped running on the treadmill, and interrupt the exercise session if the condition persists
for one minute. To change the setting, when the LED matrix shows the current duration:
USER DETECT: xxx
Press the ENTER key to change the parameter: when the current parameter value starts to blink,
press the CLEAR key to erase the current value and then use the number keys to enter the desired
new value.
Press ENTER to confirm the selection; use the + or – speed keys to move to the next or preceding
parameter.
The default value of this parameter is 5.0 km/h
The minimum threshold speed for the user detect function is 3.0 km/h. Entering any
value lower than this will have the effect of disabling the user-detect function.
At the end of the format procedure, hold down the CLEAR key for a few seconds to exit. The
CLEAR key can be pressed at any time to interrupt the procedure and revert to standby mode.
9.1.17. SN
This function shows the serial number of the machine.
9.1.18. COMMUNICATION PROTOCOLS FOR EXTERNAL MEDICAL DEVICES
This function allows to set the proper communication protocol to connect the machine to different
medical exams. medical devices as electrocardiographs or metabographs, used for tests or
o change the selection, when the LED matrix shows the current setting: T
EXT: xxx