Parameter Description Range Default value
Par 01 Default speed for Quick Start workout.
[Km/h*10]
0 - 300 10
Par 02 Default acceleration and deceleration for tread
100
belt motor. [Km/h*100/sec]
0 - 3000
Par 03 Default zero reference position for tread-belt
[*2]
-10 - +40
incline.
0
Par 04 PID proportional gain. [*100] 0 - 9999 7
Par 05 PID Integral gain. [*100] 0 - 9999 150
Par 06 Ramp Type 0 - 100 0
Par 07 Error status on DC motor encoder 0 - 1 0
Par 08 Serial communicat ion timeout [10*msec] 0 - 255 0
Par 09 DC motor encoder error timeout. [msec] 0 - 255
15
AT driver SW ≥ 2.07
Par 10 FREE - 0
Par 11 Driving roller diameter. [mm] 0 - 1000 91
Par 12 Pulley ratio 0 - 9000 200
Par 13 Error status on AC motor encoder 0 - 1 0
9.2.3. UPDOWN SETTINGS
This function allows access to the parameters in the UpDown table which define the number of
encoder pulses that correspond to different machine incline positions. To access this menu, when
the LED display shows:
UPDOWN SETTINGS
press ENTER. This function is structured as follows: