Take automatic
measurements
5. Select the tab on the Measurement Setup control window
that contains the measurement you want to take: Ampl,
Time, More, Histog, or Comm.
6. Click the button for the measurement.
The readout for the measurement and associated statistics is
automatically displayed, and the measurement is added to
the Measurements list in the control window.
Measurements are displayed in the right control window
area. If the window is occupied or there are too many
measurements to fit in that area, the measurements are
displayed in the lower graticule area.
In roll mode, measurements are not available until after you stop
acquisitions.
Note
If the waveform is clipped by the edge of the graticule, the
measurement readout will display question marks.
Remove measurements
7. To remove the measurement, click Clear. The last
measurement on the list is removed. To remove any
measurement, click the name on the Measurements list to
highlight the measurement, and click Clear. You can also
click and drag to select and clear several measurements.
8. Toggle the display of measurements on the graticule by
clicking the Display button On and Off.
Display measurement
statistics
9. From any tab on the Measurement Setup control window,
click Setup Statistics. The Measurement Statistics control
window opens.
10. From the Measurement Statistics control window, click:
 Off to turn off the display of measurement statistics
 Mean to display the mean of measurements
 All to display the Mean, Min, Max, Standard Deviation,
and Population measurements
11. To set the number of measurements included in the
measurement statistics, click Weight n=, and use the
multipurpose knobs or pop-up keypad to set the
weighting.
Set measurement
reference levels
12. From the toolbar, click Meas to open the Measurement
Setup control window.
13. From any tab on the Measurement Setup control window,

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals