TDS5000B Series GPIB Programmer Online Help
You can control the instrument via GPIB from a remote PC or via an Internet or Intranet
connection. The GPIB programming information is available as a separate WinHelp file that you
can install. See the instructions in the TDS5000B Series Product Software CD booklet.
The help file is also available as a PDF file on the TDS5000B Series Product Software CD-ROM
shipped with the instrument. Refer to the CD-ROM instructions for installation information.
TDS5000B Series Oscilloscope Applications
Software
You can install and run optional application software packages on the instrument. These software
packages provide advanced capabilities that support several applications such as jitter analysis and
disk drive measurements. Each application can be purchased and installed on the instrument at any
time. Contact your Tektronix representative for purchasing information. Follow the installation
instructions that come with the application.
Run the application software from the File menu. From the File menu, select the application from
the Run Application menu item.
Application software packages have their own online help that is separate from the main
instrument online help.
Trigger on A Event Only
Use this trigger sequence to trigger the instrument after the A event has occurred.
1 Set the A trigger type and source from the A Event tab in the Trigger Setup control
window.
2 Click the A->B Seq tab, and click A Only.
Triggering on an Event after a Specified Delay
Use this trigger sequence to trigger the instrument on the B event after a specified amount of time
after the A event.
1 Set the A trigger type and source from the A Event tab in the Trigger Setup control
window.
2 Set the B trigger type and source from the B Event tab.
3 Click the A->B Seq tab, and click Trig AfterTime.
4 Click the Trigger Delay control, and then enter the delay time between the A and B events.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals