ServicingtheQASControlManifoldCartridgeValve(continued)
g037782
Figure159
1.Poppetvalvemanifold3.LeftQASliftcylinder
2.Anglemanifold4.RightQASliftcylinder
IMPORTANT
ThesolenoidcartridgevalvesintheQASanglecontrolmanifold
(Figure157)aredifferent.Labelthevalvesbeforeremovalsothat
thevalvescanbecorrectlyinstalledintothemanifold.
IMPORTANT
AnoriceisplacedintheC3andC4portsoftheQASanglecontrol
manifold(Figure157).Ifanoriceisremovedfromthismanifold,
ensuretolabelitspositionforassemblypurposes.Wheninstalling
theoriceinthemanifoldport,ensurethattheoriceisatinthe
baseofthemanifoldport.Lettingtheoricestaycockedinthe
cavitycandamagethemanifold.
Forthecartridgevalveserviceprocedures;refertoServicingtheCartridge
ValvesinaControlManifold(page4–134).RefertoFigure157fortheQAS
anglecontrolmanifoldcartridgevalve,checkvalvesolenoidnutandplug
installationtorque.RefertoFigure158fortheQASpoppetvalvecontrolmanifold
cartridgevalveandsolenoidcoilnutinstallationtorque.
HydraulicSystem:ServiceandRepairs
Page4–176
Groundsmaster360
16225SLRevC