TECLogicChart
Eachlineofthefollowingchartidentiesthenecessarycomponentposition
(INPUTS)inorderfortheTECtoenergizetheappropriateOUTPUTSfor
machineoperation.
Example:T ostarttheenginewithnooperatorintheseat,whenthekeyswitch
isintheSTARTposition,thetractionpedalisintheNEUTRAL,andtheparking
brakeisset,theglowplugsandothernecessaryenginestartingcomponents
willbeenergized.
g187849
Figure186
Note:FortheStartmachinefunction,thePTOswitchmustbeOFFandthe
deckliftmustbeintheOFFposition.
Note:Theglowplugsareenergizedforapproximately6secondswhenthe
keyswitchisturnedfromOFFtoRUN.Theglowplugsarealsoenergizedwhen
thekeyswitchisintheSTARTposition.