DiagnosticsScreen
Thediagnosticsscreen(Figure178)listsavarietyofmachineoperationsand
thecurrentstateoftheT oroElectronicController(TEC)inputs,qualiers,and
outputsrequiredtoallowtheoperationtoproceed.Thediagnosticsscreen
shouldbeusedtotroubleshootmachineoperationissues,andcheckthat
necessarycomponentsandcircuitwiringarefunctioningcorrectly(referto
Troubleshooting(page5–28)).Toscrollthroughthelistofoperationsandselect
(highlight)theoperationtobeviewed,pressthedownbutton(asindicatedby
theatthebottomofthescreen).
Toreturntothepreviousscreen,pressthemenu/backbutton(asindicatedby
the
atthebottomofthescreen).
Foreachofthediagnosticsscreenitems,inputs,qualiers,andoutputsare
identied.Thediagnosticsscreenincludesthefollowing:
Decksidentiesthemachinerequirementsnecessarytoallowthecuttingdeck
toraiseandlower.
Inputs
QualiersOutputs
LowerInput
SeatDeckRaise(SV1)
RaiseInput
ParkingbrakeOffDeckFloat(SV2)
SteerModeindicatestheinputs,qualiers,andoutputsforswitchingbetween
2-wheelsteerand4-wheelsteer.
Inputs
QualiersOutputs
4WheelSteerSteeringonCenter4WSEnable(SV1)
SteerModeLamp
PTOidentiestherequirementsnecessarytoallowtheTECtoengagethe
cuttingdeck.
Inputs
QualiersOutputs
Input
SeatOut
LeftWingDown
RightWingDown
Groundsmaster360
Page5–21
ElectricalSystem:InfoCenterDisplay
16225SLRevC