Configuring SNMP & RMON Configuration Example
Configuration Guide
787
Figure 6-7 Enabling Rate Limit Trap
7) Click to save the settings.

Configuring RMON
1) Choose MAINTENANCE > SNMP > RMON > Statistics and click
to load the
following page. Create two entries and bind them to ports 1/0/1 and 1/0/2 respectively.
Set the owner of the entries as monitor and the status as valid.
Figure 6-8 Configuring Statistics Entry 1
Figure 6-9 Configuring Statistics Entry 2
2) Choose the menu MAINTENANCE > SNMP > RMON > History to load the following
page. Configure entries 1 and 2. Bind entries 1 and 2 to ports 1/0/1 and 1/0/2
respectively, and set the Interval as 100 seconds, Maximum Buckets as 50, the owner
of the entries as monitor, and the status as Enable.