12 Advanced Total Station Features
6. In the Measurement Information group, you can decide if an individual control point should
only be measured reflectorlessly or angle only, and can enter the correct target height, target
type, and target ID.
7.
When checking Autolock the instrument will lock on the prism automatically after the first set.
If you leave this option unchecked you will have to manually aim the total station at the prism
each time.
Tip – When adding the next point, tap Use Last Settings to copy the settings from the previous point so that you
do not have to re-enter all the values.
8.
To add and measure new control points as foresight points, tap . To configure the
point, see Step 4 through Step 5.
9.
If required, tap to check the point location of an individual point from the list and
verify that the prism is set up over the correct point.
10.
Tap to edit the configuration of each point or tap to delete it from
the list completely.
11.
Once the configuration is correct, tap Next:
12.
Tap to configure the face and round order as follows:
Tap… to…
F1 all targets only in face 1.
F1 F2 all targets only in face 1 first and then swaps in face 2 and measure all targets again.
Trimble SCS900 Site Controller Software User Guide 117

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble SCS900 and is the answer not in the manual?

Trimble SCS900 Specifications

General IconGeneral
BrandTrimble
ModelSCS900
CategoryController
LanguageEnglish

Related product manuals