Analog Input Modules
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
214
Voltage measurement
Measurement [mV] 0 = 15 bit + sign 12 bit
50 100 500 1000
dec. hex. dec. hex.
-50 -100 -500 -1000 -31768 8000 -32768 8000
-49.998 -99.997 -499.985 -999.969 -32767 8001 -32767 8001
-49.976 -99.951 -499.756 -999.512 -32752 8010 -32752 8010
-0.024 -0.049 -0.244 -0.488 -16 FFF0 -16 FFF0
-0.002 -0.003 -0.015 -0.031 -1 FFFF 0 0000
0 0 0 0 0 0000 0 0000
0.002 0.003 0.015 0.031 1 0001 0 0000
0.024 0.049 0.244 0.488 16 0010 16 0010
49.951 99.902 499.512 999.023 32736 7FE0 32736 7FE0
49.997 99.994 499.969 999.939 32766 7FFE 32752 7FF0
49.998 99.997 499.985 999.969 32767 7FFF 32752 7FF0