Technology Modules
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
384
Behavior of the DI digital input
The digital input can be run with different sensors (positive switch or push-pull).
The input signal can be inverted (exception: in Latch and retrigger function).
The STS_DI status bit indicates the status of the digital input.
The following digital input functions are available for selection in count mode:
Digital input
Hardware release (HW gate)
Latch retrigger function when edge positive
Synchronization when edge positive
The following digital input functions are available for selection in measurement mode:
Digital input
Hardware release (HW gate)
Behavior of the digital outputs DO1/DO2
Count mode
The digital outputs can be activated depending on the counter status and reference values.
The module is provided with a ”real” digital output and a virtual” digital output that is only present
as a status bit in the check-back interface/process input.
Two reference values can be stored on the counter module and assigned to the digital outputs sep-
arately.
The following functions can be selected:
Output (no switching via comparator)
Set if counter value reference value
Set if counter value reference value
Pulse if counter value = reference value
Comparison results for comparator 1 are assigned to the physical output DO1.
Comparison results for comparator 2 are assigned to the virtual output DO2.
Permissible value range for the two reference values