Technology Modules
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
428
REG_CMP2 35 Reference value 2 0×0000 0000
REG 36…47 reserved
REG_LOWER_
LIMIT
48 Lower limit 0×0000 0000
REG_UPPER_
LIMIT
49 upper limit 0×FFFF FFFF
REG_OFFSET 50 Offset value 0×0000 0000
REG_SSI_MASK 51 Selection of the SSI encoder diag-
nostics transferred to the diagnos-
tics interfaces.
0×0000 0000
REG 52…63 reserved
Designation Interfaces
Process
output
Storage in moduleProcess input Param. Diagn.
REG_SSI_POS 0 RD
REG_MAGIC_NO 1 RD
REG_HW_VER 2 RD
REG_SW_VER 3 RD
REG_SF 4 WR volatile RD
REG_WR_ADR 14 RD
REG_RD_ADR 15 RD
REG_DIAG1 16 RD RD
REG_PARA1 20 WR non volatile RD WR
REG_GRAY_POS 32 RD
REG_SSI_FRAME 33 RD
REG_CMP1 34 WR volatile RD
REG_CMP2 35 WR volatile RD
REG_LOWER_LIMIT 48 WR non volatile RD
REG_UPPER_LIMIT 49 WR non volatile RD
REG_OFFSET 50 WR non volatile RD
REG_SSI_MASK 51 WR non volatile RD
NOTE
The non volatile registers can be written maximum 100.000 times.
Designation No. Description Default (HEX)