EasyManua.ls Logo

turck BL20 Series - Page 433

turck BL20 Series
537 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
431
2020/09
Masking with REG_SSI_MASK
The following applies to bit 0 (SSI group diagnostics) of the diagnostics interface and SSI_DIAG of
the process input data:
(SSI_STS0 & EN_D0_DS) ||(SSI_STS1 & EN_D1_DS) || (SSI_STS2 & EN_D2_DS) || (SSI_STS3 &
EN_D3_DS)
Resetting the register bank
If register REG_SF is written with the signature:
„LD20” = 0 × 6C643230
all default values of the retentive registers (incl. parameter registers) are reset.
If register REG_SF is written with the signature:
„LD48” = 0 × 6C643438
all default values of the retentive registers except the parameter registers are reset.
Process input data REG_SSI_MASK
Byte Bit 7 Bit 6 B 5 B 4 B 3 B 2 B 1
SSI_STS0 0 EN_ D0_RMS0 EN_D0_DS - SSI_FRAME_BIT_SEL0
SSI_STS1 1 EN_ D1_RMS1 EN_D1_DS - SSI_FRAME_BIT_SEL1
SSI_STS2 2 EN_ D2_RMS2 EN_D2_DS - SSI_FRAME_BIT_SEL2
SSI_STS3 3 EN_ D3_RMS3 EN_D3_DS - SSI_FRAME_BIT_SEL3
Designation Value Description
EN_D×_RMSx 0 The transfer of the SSI status messages to the process input data is not
activated
1 The transfer of the SSI status messages to the process input data is acti-
vated
EN_ D×_DS 0 The evaluation of the SSI status messages for bit 0 of the diagnostics is
not activated
1 The evaluation of the SSI status messages for bit 0 of the diagnostics is
activated.
SSI_FRAME_BIT_SEL 0-31 Definition of the selected bits in the frame of the SSI encoder to be
evaluated or copied.
default 0
NOTE
Overwritten values are lost.all default values of the retentive registers (incl. parameter reg-
isters) are reset.

Table of Contents

Related product manuals