Advance Information
change its current configuration immediately after receiving a configuration message. The receiver will always
use the current configuration only.
The current configuration is loaded from permanent configuration hard-coded in the receiver firmware (the
defaults) and from non-volatile memory (user configuration) on startup of the receiver. Changes made to the
current configuration at run-time will be lost when there is a power cycle, a hardware reset or a (complete)
controlled software reset (see chapter Forcing a Receiver Reset in the Integration Manual).
See the Configuration Interface section for a detailed description of the receiver configuration system, the
explanation of the configuration concept and its principles and interfaces.
The configuration interface has changed from earlier u-blox positioning receivers. There is some
backwards compatibility. Users are strongly advised to only use the Configuration Interface referred
to in the following sections. See also Legacy Configuration Interface Compatibility.
See the Integration Manual for a basic receiver configuration most commonly used.
UBX-18010854 - R04 Advance Information Page 4 of 259