15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| TRIGIN Current Trigger Period in 1/8km (0.83333 usec) Steps | Output 3
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Current Sample of TAG bits 15–0 | Output 4
|-------------------------------|--------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Current Sample of TAG bits 31–16 | Output 5
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| 0 0 | (MSB) Log of Measured Noise Level(LSB) | Output 6
|-------|--------------------------------------------------------|
This value is scaled four times higher than the time series LOG format (see 8.8 Initiate
Processing (PROC) (page 255)). To convert to dBm, use the equation:
=
+ ×
4
3584
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| ”I” Channel Measured DC Offset | Output 7
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| ”Q” Channel Measured DC Offset | Output 8
|-------------------------------|--------------------------------|
RVP900 User Guide M211322EN-J
274