EasyManua.ls Logo

Vaisala RVP900 - Debugging and Profiling Your Code; Monitoring Opcode;Data Activity: -exposeIO

Vaisala RVP900
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D.7.2 TS Recording on a Local RVP900
Figure 63 TS Record on Local RVP900
In this example, the TS Switch is set to place the real-time IQ values from the IQ-Data
Process into the TS API. These are extracted and recorded to local disk by the tsarchive
process.
While TS data are being recorded, RVP900 may still do its normal data processing tasks, as
shown in D.7.1 RVP900 in Normal Real-Time Operation (page 401) .
Utility Settings
TS Switch: Local RVP900
TS Archive: Record
This configuration records to a local disk on RVP900. Recording to a dedicated data
partition, NOT the “/” partition. This is because if the “/” partition fills-up, the system
crashes.
If the separate data partition fills-up, then the system stops recording, but otherwise
functions normally.
D.7.3
 TS Recording on Separate Archive Host
This is the recommended recording configuration for TS recording.
RVP900 User Guide M211322EN-J
402

Table of Contents

Other manuals for Vaisala RVP900