Vaisala RVP900 - Interface Output Test (OTEST)

Vaisala RVP900
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Filter for Range Bin #2 | Filter for Range Bin #1 | Input 1
|-------------------------------|--------------------------------|
Total of Ceil(NBins/2) Words Loaded
8.10 Get Processor Parameters (GPARM)
Use GPARM to access status information from the RVP900 processor.
64 words are always transferred. Some words are reserved for future compatibility and are
read as zeros.
Table 70 RVP900 Status Output Words
Word Description
1 Revision/Serial number
2 Number of Range Bins
3 Current trigger period
4 Current TAG00 - TAG15
5 Current TAG16 - TAG31
6 Log of Measured Noise Level
7 I Channel DC Oset
8 Q Channel DC Oset
9 Latched Processor Status
10 Immediate Status Word #1
11 Diagnostic Register A
12 Diagnostic Register B
13 Number of Pulses/Ray
14 Trigger Count (Low 16-bits)
15 Trigger Count (High 8-bits)
16 No. of Properly Acquired Bins
17 No. of Properly Processed Bins
18 Immediate Status Word #2
19 Noise Range in Km
Chapter 8 – Host Computer Commands
271