8.22 Load Clutter Filter Specifications
(LFSPECS)
RVP900 allows 7 dierent clutter filters (plus the fixed all-pass filter) to be resident at once,
so that an appropriate filter can be selected and applied to each processed ray based on
Range, Azimuth, and/or Elevation. The LFSPECS command allows this suite of
filters to be
redefined on the fly.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| | 0 0 0 0 0 0 0 1 1 1 1 1 | Command
|---------------|------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| | Filter # | Input 1
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Filter Type | Input 1
|----------------------------------------------------------------|
Variable number of XARGS depending on Filter Type
The Filter # tells which
filter definition slot is being modified, and the Filter Type
tells the type of clutter filter to construct.
Chapter 8 – Host Computer Commands
307