Characteristic Description
Input power RVP901 IFDR:
100 VAC ... 240 VAC
50 Hz ... 60 Hz auto-ranging ±5%
RVP902 Main Chassis:
100 VAC ... 240 VAC
50 Hz ... 60 Hz auto-ranging
Power consumption RVP902/Main Processor: 1300 W
RVP901 IFDR maximum power consumption: 50 W
RVP901 IFDR IF Digitizer: 50 W
Environmental RVP901 with DC Option: -40°C ... +50°C (-40°F ... +122°F), 0% ... 95% R.H.
(non-condensing) with a minimum of 20 cubic feet per minute of air-flow.
RVP901 with AC Option: -40°C ... +45°C (-40°F ... +122°F), 0% ... 95% R.H.
(non-condensing) with a minimum of 20 cubic feet per minute of air-flow.
RVP902: 10°C ... 35°C (50°F ... 95°F), 8% ... 90% R.H. (non-condensing) at
altitudes less than 2000 m for Rev C and D, and at altitudes less than 5000
m for Rev E.
Reliability
Digital receiver
MTBF>50,000 hours (at 25°C/77°F)
<1 hour MTTR
9.10 Type Plate
The type plates identify RVP902 and RVP902-IO parts.
Figure 52 RVP902 Type Plate
Chapter 9 – Technical Data
337