The TASKID command defines a 16-character Null-terminated name, along with a 16-bit
sweep number and 16-bit auxiliary (user defined) number.
You may use all 16 characters of the name, as it is stored internally in 17 slots.
The Sweep Number and Scan Geometry (one of SCAN_xxx parameters) should be
filled in with values best approximating those notions. Auxiliary Number may be filled
in with any value that you find meaningful.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| | 0 0 0 1 0 1 1 1 1 1 1 1 | Command
|---------------|------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Sweep Number | Input 1
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Auxiliary (User Defied) Number | Input 2
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Name Byte–2|Name Byte–1 | Input 3
|-------------------------------|--------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| |Scan Geometry | XARG 1
|-------------------------------|--------------------------------|