1-84 Engine Mechanical Industrial 1.6L
Coolant Thermostat, Remove and Install
Refer to operation Coolant Thermostat, Remove and Install
in Section 2, Engine Cooling.
Fuel Pressure, Check
Important: Fuel escapes. Observe safety regulations and
national legislation.
Installation Procedure
1. Connect Pressure Gauge KM–J–34730–91 (1) to test
connection (2).
2. Start engine and bleed pressure gauge – idle speed.
Collect escaping fuel in a suitable container.
Inspect
1. Check fuel pressure.
2. Start engine and allow to run at idle speed. Nominal
value – see relevant Checking Procedures.
Removal Procedure
1. Detach pressure gauge from test connection.
Coolant Pump, Remove and Install
Refer to operation Coolant Pump, Remove and Install in
Section 2, Engine Cooling.