UL 325 COMPLIANT SENSORS
All external entrapment protecon
sensors must have NC sensor outputs
and be wired to the SENSOR COM
terminal for monitoring and powering
purposes. Depending on soware
version, the sensor becomes powered
when the gate operator’s motor
runs or is always powered when the
operator is connected to AC power.
UL 325 Compliant Sensors
The following sensors have been tested with Nice | HySecurity gate operators by an independent
laboratory and cered to comply with UL 325 7th Edion. Select sensors from this list for UL compliant
gate automaon soluons. Contact the sensor manufacturer for specic recommendaons for use.
Recommended External Entrapment Protecon Sensors List for the SmartDC Controller – Kinec Operator
Mfg. Part # or Model Brand Wallace Perimeter
Security Part #
Max. Range
Photo Eyes
(Retro-reecve)
E3K-R10K4-NR-1 Omron - 40 (12.2m)
NIR-50-325 EMX - 45 (13.7m)
IRB-RET EMX - 53 (16.1m)
E-931-S50RRGQ Seco-Larm - 46 (14m)
Photo Eyes
(Thru-Beam)
OVS-50TNR Optex - 33 (10m)
IRB-MON EMX 100620 65 (19.8m)
E-960-D90GQ Seco-Larm - 90 (27.4m)
Edge Sensors Senr Series ASO Safety 100543 -
CPT210-2U-#-T2 Miller Edge - -
Edge Sensor
Converters
Hy2NC (Converts 10K to
NC Monitoring)
HySecurity - -
Mul-Input Module The Soluon – MIM-62 Miller Edge - -