Alpha/Delta (Kinetic Operator) Installation and Maintenance Manual Revision 1 - MAY 2023
181
KINETIC DC SPECIFICATIONS
Kinec DC Specicaons
Model Kinec DC 15W [Kinec 1] Kinec DC 10FW [Kinec 2]
Kinec Solar:
DCS 15W [Kinec 1S]
DCS 10FW [Kinec 2S]
Max. Gate Length 30  (9.14 m) 30  (9.14 m) 30  (9.14 m)
Max. Gate Weight 1,500 lbs (680kg) 1000lbs (454kg)
DCS 15W = 1,500lbs (680kg)
DCS 10FW = 1,000lbs (454kg)
Gate Speed 1/s 2/s 1/s and 2/s, respecvely
UPS Operaon on
Baeries only
Up to 4,000 of gate travel
(1,219 m)
Up to 4,000 of gate travel
(1,219 m)
Up to 1,500 (457m) of gate
travel per day (8Ah baeries fully
charged)
Duty Cycle Connuous Connuous Connuous
Power: Single phase
(switch selectable)
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
Solar-powered (24VDC, two 20
WATT panels) 70 cycles/day in a
full sun for 3 hours
Horsepower ½ hp ½ hp ½ hp
Accessory Power 1 amp each at 12VDC and 24VDC 1 amp each at 12VDC and 24VDC 1 amp each at 12VDC and 24VDC
Communicaon USB, RS232, RS485 USB, RS232, RS485 USB, RS232, RS485
Temperature Rang -13°F to 158°F (-25°C to 70°C) -13°F to 158°F (-25°C to 70°C) -13°F to 158°F (-25°C to 70°C)
Cercaon 500,000 cycles 500,000 cycles 500,000 cycles
DC Baeries Two 8Ah (50Ah oponal) Two 8Ah (50Ah oponal) Two 8Ah (50Ah oponal)
Est. Shipping
Weight
160 lbs (73 kg) 160 lbs (73 kg) 150 lbs (68 kg)
UL Lisng Class I, II, III, IV Class III, IV
DCS 15W = Class I, II, III, IV
DCS 10FW = Class III, IV
Warranty
5 years commercial use (7 years
for single-family residence)
5 years commercial use
5 years commercial use (7 years
for single-family residence)
To enable fully automac operaon, all SLIDE gate operators require a minimum of TWO monitored external
entrapment protecon sensors (one for each direcon) to protect entrapment zones in both the open and
close direcon of travel. Visit hps://support.hysecurity.com/hc/en-us/categories/360003177593-Safety
for more informaon on UL 325 standards and gate safety.

Table of Contents