EasyManua.ls Logo

Wallace Perimeter Security ALPHA - DC Battery Replacement

Default Icon
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176
wallaceperimetersecurity.comPhone: 866.300.1110
DC BATTERY REPLACEMENT
DC Baery Replacement
Wallace Perimeter Security provides a one-year warranty from the date of shipment for all the baeries
supplied with the Kinec operator.
Indicators of a low baery include:
LOW BATTERY or DEAD BATTERY appears on the SmartDC Controller display which may or may not
be indicave of normal discharge.
Alert 18 CHANGE BATTERY appears on the SmartDC Controller display. The operator emits an
audible chirp every minute to indicate a problem exists.
AP (#) AC LOSS appears on the SmartDC Controller display. Gate operaon is aected by AC power
loss depending on customer preferences and the conguraon set by the installer in the AP (#) AC
LOSS User Menu.
For detailed informaon about the
AP AC LOSS conguraon, refer
to “Seng AC Power Loss Gate
Funcon” on page 92.
Symptoms of a low baery may include:
Gate remains locked in the open posion.
Gate remains locked in the closed posion.
Gate opens ve seconds aer AC power loss and locks open.
Before replacing the baeries, turn
o all power switches. Use only
AGM baeries as Replacements 8Ah
- MX002008, 50Ah - MX002013).
The baeries supplied in the Kinec
operator are state-of-the-art AGM
baeries. Do NOT use ooded cell
baeries as damage may occur to
the unit. Wear protecve clothing
while working with baeries.

Table of Contents