VEHICLE DETECTOR AND LOOP FAULT DIAGNOSTICS
Vehicle Detector and Loop Fault Diagnoscs
If HY5B vehicle detector modules are used, the SmartDC Controller has the ability to store and report
detector and loop fault informaon for performance diagnoscs.
If the SmartDC Controller senses a loop or detector problem:
• The LCD display ashes the name of the aected detector or error and the appropriate alert code.
• The buzzer chirps connuously at regular intervals unl the issue is resolved.
Table 13. HY5B Vehicle Loop Detector Faults and Errors
Alert or Error
# LCD Descripon Advisory Resoluon
ALERT 7 FREQ SHIFT FAULT HY5B vehicle detector –
Abnormal frequency change
alert.
The alert indicates an unstable loop
frequency. Check the loop and lead-in wires
for problems. Replace them, if necessary.
ALERT 8 LOOP SHORTED HY5B vehicle detector –
Loop is shorted.
The alert indicates that the loop and lead-
in wires are shorng out. Check the wires
for problems. Replace them, if necessary.
ALERT 9 LOOP OPEN HY5B vehicle detector -
Disconnected loop alert.
The alert indicates the loop wires are
loose or disconnected. Check the wires
for problems. Replace them, if necessary.
ALERT 10 I²C BUSS ERROR HY5B vehicle detector -
Communicaons alert.
The alert indicates the detector is not
communicang properly with the SmartDC
Controller. The alert occurs if the detector
is unplugged or the connecon is unstable.
If communicaon is not re-established
within 30 seconds, the controller will reset
and the message changes to ERROR 3.
ALERT 11 DETECTOR FAULT HY5B vehicle detector -
Malfuncon alert.
The display indicates the HY5B
detector malfuncon. Check detector
for problems. Replace it, if necessary.
ALERT 12 ON TOO LONG Detector input triggered too
long –
More than ve minutes.
The display indicates the HY5B detector
malfuncon. The alert also works for any
input connected to the terminal strip for
standard box detectors. Check that a vehicle
is not parked on the loop. Also, determine
if the loop is stable. An unstable loop can
hold the detector in a triggered state.