162
wallaceperimetersecurity.comPhone: 866.300.1110
TROUBLESHOOTING
Table 12. SmartDC Controller - Troubleshoong
Ref.
No�
Display Descripon
Possible Causes Soluons
Condion Alert, Error or Fault
46 ERROR 8
RPM SENSOR
RPM sensor
disconnected.
Motor Encoder or wires are
damaged or unplugged.
Check wiring from the motor
to the SmartDC Controller
board.
47 ERROR 9
BATTERY
DISCONNECT
The SmartDC Controller
detected there is no
baery connected.
The baeries are
disconnected, or a wiring
fault exists. Kinec
operators ship with a wire
disconnected to prevent
baery drain.
Replaced by Alert 28 in
h5.57 soware version for
AC powered operators.
1. Ensure the red wire in the
upper le corner of the
control box is connected to
the switch.
2. Correct any losses with
baery wiring.
3. Check the 35-amp fuse on
the circuit board.
48 ERROR 10
SLOWDOWN
SWITCH
Not used in Kinec
operators.
N/A N/A