1680-2414 Rev. A Made in the U.S.A.
December 2018
User’s Guide
Registered Company
Winona, Minnesota USA
ISO 9001
TOTAL
3 Year Warranty
CUSTOMER
SATISFACTION
F4T Controller
Setup and Operations
1241 Bundy Boulevard., Winona, Minnesota USA 55987
Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507
http://www.watlow.com/F4T.cfm

Table of Contents

Other manuals for Watlow F4T

Questions and Answers

  • A
    Angela HorneAug 31, 2025
    What to do if my Watlow Controller has no display?
    • T
      Tina MaldonadoSep 1, 2025
      If your Watlow Controller has no display, there could be several reasons: * The power to the controller might be off, so turn the power on. * A fuse might be open, in which case you should replace the fuse. * The breaker might be tripped, so reset the breaker. * The safety interlock switch might be open, so close the interlock switch. * A separate system limit control might be activated, so reset the limit. * There may be a wiring error; correct the wiring issue. * The voltage to the controller may be incorrect; apply the correct voltage and check the part number.
  • G
    gonzalezjenniferSep 13, 2025
    What does loop reversed error mean on my Watlow F4T?
    • J
      Joseph HallSep 13, 2025
      A loop reversed error on your Watlow Controller may occur due to: * An incorrect setting of the Open Loop Detect Time. Set the correct Open Loop Detect Time for the application. * An incorrect setting of the Open Loop Detect Deviation. Set the correct Open Loop Deviation value for the application. * An output programmed for an incorrect function. Set the output function correctly. * A thermocouple sensor wired in reverse polarity. Wire the thermocouple correctly (red wire is negative).
  • L
    Luis JohnsonAug 30, 2025
    How to fix loop reversed error on Watlow Control Unit?
    • J
      Jessica LoweAug 30, 2025
      To correct a 'Loop Reversed Error' on your Watlow Control Unit, set the correct Open Loop Detect Time and Deviation value for your specific application. Ensure the output function is correctly set. Check the thermocouple wiring, making sure the red wire is connected to the negative terminal.
  • O
    Olivia ThompsonSep 15, 2025
    How to fix no display on Watlow Control Unit?
    • T
      Timothy WilliamsSep 15, 2025
      To address a 'No Display' issue on your Watlow Control Unit, start by ensuring the controller is receiving power by turning it on. If power is on, check and replace the fuse if necessary, reset the breaker, and ensure the interlock switch is closed. Also, reset the limit and verify the wiring. Finally, confirm the correct voltage is being applied and check the part number.
  • D
    Debbie MckinneySep 14, 2025
    Why is the time and date wrong on my Watlow Controller?
    • A
      Amy RodriguezSep 15, 2025
      The time and date may be wrong on your Watlow Controller because: * A battery is not installed. Install the battery per the instructions. * The polarity is reversed. Place the battery with the positive side facing up in the holder. * The battery is bad. Replace the battery.
  • Q
    qyoungSep 22, 2025
    What does limit high mean on Watlow Control Unit?
    • M
      matthew54Sep 22, 2025
      To address a 'Limit High' indication on your Watlow Control Unit, first verify if the temperature exceeds the limit set point and check what is causing the over-temperature condition. Clear the limit and establish the correct limit set point.
  • N
    Nicole JonesAug 27, 2025
    What to do for heater error on Watlow Control Unit?
    • C
      cgarrettAug 27, 2025
      To address a 'Heater Error' on your Watlow Control Unit, check that the load current is proper. If the current through the load is above the current trip set point, correct the cause of the overcurrent and ensure the current trip set point is correct. Also, check that the load current is proper. Correct the cause of the undercurrent and ensure the current trip set point is correct.
  • R
    robert39Aug 26, 2025
    How to fix limit error on Watlow Control Unit?
    • E
      Ethan NelsonAug 26, 2025
      To solve a 'Limit Error' on your Watlow Control Unit, check for improperly wired or open sensors and correct the wiring or replace the sensor. Ensure that the setting matches the sensor used and check the calibration of the controller.
  • R
    robertbarnesAug 25, 2025
    What causes alarm error on Watlow Control Unit?
    • J
      Jeffrey OrtizAug 26, 2025
      To resolve an 'Alarm Error' on your Watlow Control Unit, first check if the sensor is improperly wired or open. If so, correct the wiring or replace the sensor. Also, make sure the setting matches the sensor being used and check the calibration of the controller.
  • W
    William ColemanAug 25, 2025
    What to do if alarm won’t clear on Watlow Control Unit?
    • J
      johnsonwilliamAug 25, 2025
      If your Watlow Control Unit's alarm won’t clear or reset, try the following: Reset the alarm when the process is within the specified range or disable latching. Ensure the output is set to the correct alarm source instance and the alarm source is set to the correct input instance. Correct any sensor input issues that are causing it to be out of the alarm range. Also, verify the alarm set point is at the correct trip point and that the alarm is set to the correct type (process, deviation, or power). Finally, check the digital input function and source instance.

Summary

Chapter 1: Overview

Available F4 T Literature and Resources

Lists available documentation and resources for the F4T controller.

Technical Assistance

Provides contact information and steps for obtaining technical support.

Document Overview and Purpose

Explains the scope and purpose of the F4T User's Guide.

A Conceptual View of the F4 T System

Provides a high-level overview of the F4T controller's architecture and functionality.

Chapter 2: Composer Software

Installing Composer Software

Step-by-step guide for installing the Composer software on a PC.

Using Composer Software

Instructions on connecting to the controller and navigating Composer's interface.

Configuring Pluggable Flex Modules

Details on how to configure and manage Flex Modules installed in the controller.

Creating and Editing Profiles Using Composer

Guide to creating, editing, and managing profiles for the F4T controller.

Chapter 3: Using the F4 T Front Panel

Navigating and Understanding the User Interface (UI)

Explains the structure and navigation of the F4T's front panel menus.

Home Screen Described

Details the components and layout of the F4T's configurable home screen.

Data Logging

Instructions for setting up and initiating data logging on the F4T controller.

Chapter 4: Application Examples

Single Loop Control

Demonstrates a basic single loop control configuration using the F4T controller.

Heat and Cool Control Loop

Explains a heat and cool control loop application example.

Cascade Control

Details how to configure and use cascade control for improved process management.

Compressor Control

Explains how to coordinate compressor demands for cooling/dehumidification.

Chapter 5: Function Block Reference

F4 T Functions Described

Overview of function blocks, signals, and error status within the F4T system.

Alarm

Explains how to use the alarm block to monitor signals and trigger outputs.

Control Loop

Details how to use control loop blocks for temperature or other process value manipulation.

Math

Describes various mathematical operations available for signal processing.

Chapter 6: Appendix

Communications

Information on communication protocols like Modbus TCP and SCPI.

F4 T Base Ordering Information

Provides details on how to order F4T base units and their configurations.

Flex Modules and Limit I;O Specifications

Technical specifications for Flex Modules, including I/O capabilities and limits.

Declaration of Conformity

Lists the product's compliance with various electrical and safety directives.

Watlow F4T Specifications

General IconGeneral
InputsThermocouple, RTD, mA, V
OutputsRelay, SSR, mA, V
CommunicationEthernet, Modbus RTU
Data LoggingYes
CertificationsCE, UL, cUL, RoHS
Control ModesPID, On/Off
Power Supply100 to 240 VAC
Operating Temperature0 to 50°C
Enclosure RatingIP65
Display4.3 in. (109 mm) color touch panel LCD
Control LoopsUp to 4