Maintenance3206−1/A1
Winterthur Gas & Diesel Ltd.
2/ 2
2. Tooth Checks
2.1 Lubricant Instructions
Apply a very thin, equal layer of lubricant to the tooth flanks of the pinion (2, Fig. 1)
and the flywheel (3). Refer to Table 1 and Table 2.
Table 1: Instructions − Pyroshield
Manufacturer Location Instruction
LE 5182
Pyroshield
Apply a thin layer of the
lubricant to the teeth as shown
in the photograph.
Table 2: Instructions − Klüberfluid
Manufacturer Location Instruction
Klüberfluid
C−F 3 Ultra
Increase the temperature of
the Klüberfluid.
Put an applicable quantity of
Klüberfluid into a container.
Put the container into warm
water until the Klüberfluid is at
approximately 35_C.
Apply the Klüberfluid as shown
in the photograph.
2.2 Lubrication Intervals
1) Look at the tooth flanks. If the highest loaded areas of the tooth flanks do not have
much lubricant, apply the lubricant as given in Table 1, or Table 2.
2) Apply the lubricant each 2000 operation hours, or as necessary.
2.3 Recommended Suppliers
Lubrication Engineers Inc.
300 Bailey Avenue
Forth Worth, TX
USA
http://www.lelubricants.com/
Email: info@le-inc.com
Klüber Lubrication München KG
Geisenhausenerstrasse 7
81379 München
Germany
http://www.klueber.com
Email: info@klueber.com
2015
Turning Gear: Teeth and Screwed Connections − Check