EasyManua.ls Logo

WinGD X92 - Relief Valve; 5562−2;A1

Default Icon
574 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
55622/A1
Winterthur Gas & Diesel Ltd.
1/ 3
Removal, Check, Installation
Tools:
1 OBEL test bench 94272 2 Pressure gauge 94934A
1 Valve holder 94272A 2 HP hoses 94935
1 HP oil pump 94931
1. General 1..........................................................
2. Removal 2.........................................................
3. Relief Valve Test 2..................................................
3.1 Test and Calibration Fluid Physical Conditions 2..............
3.2 Preparation 2.................................................
3.3 Sealing Pressure Check 2.....................................
3.4 Operation Pressure Check 2...................................
4. Installation 3.......................................................
1. General
Maintenance of the relief valve (1, Fig. 1) is not usually necessary, but you must do a
function check at regular intervals. Refer to the Maintenance Schedule 03801 Relief
Valve for the frequency to do the function test. Unserviceable relief valves must be
sent to the manufacturer, or a Wärtsilä Switzerland Ltd. authorized repair workshop
for inspection and repair.
The International Association of Classification Societies (IACS) approval is given for:
D The type of test
D The type of certificate
D The frequency of the test.
The results of the test must be recorded on the Inspection Report.
Note: The two bores (2) identify the relief valve (1) as a new item.
Fig. 1
1
4
AF80
WCH02959
2
Applicable pressure that
opens the relief valve
3
I
I
II
II
II - II
1
4
WCH02959
WCH02959
Fuel Rail
Relief Valve
2015

Table of Contents

Related product manuals