Maintenance5564−1/A2
Winterthur Gas & Diesel Ltd.
2/ 5
3. Removal
WARNING
Fire Hazard: Do not weld or
grind materials in the work
area. Sparks can cause a
fire.
WARNING
Injury Hazard: Put on
gloves and safety goggles
before you do work on hot
components. Fuel and oil
can come out as a spray
and cause injury.
WARNING
Injury Hazard: Do not
operate the turning gear.
Fuel can come out of the
opening in the fuel rail.
1) Remove the pipes (2, 3 and 4, Fig. 2)
from the ICU (1).
2) Disconnect the electrical connection
from the fuel quantity sensor (5).
3) Disconnect the electrical
connections (6) from the rail valves (5).
4) Apply protection to the openings on the
ICU (1, 2 and 3, Fig. 3).
5) Apply protection to the open ends of
the pipes that you removed in step 4).
6) Remove the three bolts (4). Use long
hex head drivers 94022A−10L.
2015
Injection Control Unit: Removal and Installation
Fig. 2
WCH02792
1
2
3
4
4
7
6
I
I
Fig. 3
3
1
2
WCH02792
5