Maintenance
55641/A2
Winterthur Gas & Diesel Ltd.
5/ 5
14) Remove the protection from the pipes
and openings and from the openings in
the ICU.
15) Install the pipes (2, 3 and 4, Fig. 9) to
the ICU.
16) Connect the electrical connection to the
fuel quantity sensor (5).
5. Completion
1) Install the HP fuel pipes, refer to 8733.1.
2) Cut in the injection, refer to the Operation Manual, 05101.
3) Operate the engine for a minimum of 1.5 hours with marine diesel oil. For more data,
refer to the Operation Manual 05101.
6. Storage
Before you put an ICU into storage, do the procedure that follows:
1) Use a vacuum cleaner to remove dirt from all openings.
2) Clean the ICU.
3) Lubricate the ICU correctly.
4) Put the ICU in a plastic bag.
5) Remove as much air as possible from the plastic bag.
6) Seal the plastic bag.
2015
Injection Control Unit: Removal and Installation
WCH02792
1
2
3
4
I
5
Fig. 9