Maintenance
5562−2/A1
Winterthur Gas & Diesel Ltd.
3/ 3
013.484/05
013.486/05
94935
94934A
94272A
1
2
94272
94931 3 94934A
Fig. 2
4. Installation
1) Apply Never-Seez NSBT to the thread of valve housing (2, Fig. 3).
2) Install the relief valve (1) in the connecting piece (3).
3) Torque the relief valve (1) to 300 Nm.
Fig. 3
1
3
AF80
WCH02959
2
1
WCH02959
Fuel Rail
2015
Relief Valve: Removal, Check, Installation